beautypg.com

Axlink wiring guidelines, Wiring axlink with optional 12 vdc power supply – AMX AXB-MIDI User Manual

Page 8

background image

Installation

4

AXB-MIDI MIDI Interface

AXlink Wiring Guidelines

The following table lists wire sizes and maximum lengths allowable between the AXB-MIDI and

the Central Controller power supply. The maximum wiring lengths are based on 13.5 VDC @ 100

mA available at the Central Controller's power supply output cable end.

If the AXB-MIDI is installed farther away from the Central Controller than recommended, connect

an optional 12 VDC power supply to the AXlink connector on the AXB-MIDI rear panel (see the

Wiring AXlink with Optional 12 VDC power supply section on page 4).

Wiring AXlink with Optional 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink connector on the rear panel of the

AXB-MIDI, as shown in FIG. 4.

Use an external 12 VDC power supply when the distance between the Central Controller and

AXB-MIDI exceeds the limits described in Figure 9 or the power supply current capacity cannot

FIG. 3 AXlink wiring

PWR +

AXP/TX

AXM/RX

GND -

PWR +

AXP/TX

AXM/RX

GND -

AXB-MIDI

Central Controller

If using power from AXlink, disconnect the wiring from the Central Controller before
wiring the AXB-MIDI.

AXlink Wiring Guidelines

Wire Size Max Wiring Length

18 AWG

1,173.71 ft (357.74 m)

20 AWG

742.57 ft (226.34 m)

22 AWG

462.96 ft (141.11 m)

24 AWG

291.83 ft (88.95 m)

FIG. 4 Wiring AXlink with Optional 12 VDC power supply

PWR (+)

GND (-)

Local +12 VDC power supply
(coming from the PSN power supply)

PWR +

AXP/TX

AXM/RX

GND -

PWR +

AXP/TX

AXM/RX

GND -

AXB-MIDI