Operation condition – Panasonic CSE10KD3EA User Manual
Page 4

4
OPERATION CONDITION
OPERATION CONDITION
OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range
(CU-E10HBEA)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Maximum
32
23
43
26
Minimum
16
11
-10
-
HEATING
Maximum
30
-
24
18
Minimum
16
-
-10
-
NOTICE: • This unit is still able to operate as a cooler with outdoor temperature as low as -10°C in a non-living room, such
as a computer room, with a room temperature of 16°C or above, and room humidity up to 80%. When the
outdoor temperature drops to -10°C, compressor will be cut off and resume operation again once the temperature
rises to more than -10°C.
• When the outdoor temperature is out of the above temperature range, the heating capacity will drop signifi cantly
and outdoor unit might stop for protection control.
(CU-2E15LBE, CU-2E18LBE, CU-4E27CBPG)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Maximum
32
23
43
26
Minimum
16
11
16
11
HEATING
Maximum
30
-
24
18
Minimum
16
-
-10
-11
(CU-3E18LBE, CU-4E23LBE)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Maximum
32
23
46
26
Minimum
16
11
-10
-
HEATING
Maximum
30
-
24
18
Minimum
16
-
-15
-16
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature