beautypg.com

Technical specifications – Alcatel-Lucent 7450 User Manual

Page 5

background image

Alcatel-Lucent 7450 Ethernet Service Switch | Data Sheet

5

Technical specifications

Per IOM CaPaCIty

7450 eSS IOM3-XP

7450 eSS IOM-1

Slot requirements

• Single-slot module

• Single-slot module

MDA/ISA supported per IOM

• Two MDAs or ISAs

• Two MDAs or ISAs

MDA type supported

• MDA and MDA-XP

• MDA and MDA-XP

IOM full-slot throughput

• 50 Gb/s

• 20 Gb/s

MDA per-half-slot throughput

• Up to 25 Gb/s per MDA for a total of

• Up to 10 Gb/s per MDA for a total of

50 Gb/s per IOM

20 Gb/s per IOM

Indicators

• Operational: Solid green; Fault: Amber

• Not applicable

Supported chassis

• 7450 ESS-12

• 7450 ESS-12

• 7450 ESS-7

• 7450 ESS-7

• 7450 ESS-6

• 7450 ESS-6

Minimum operating system software

• SR OS Release 6.1

• SR OS Release 4.0 or higher MDA support varies

by SR OS release

Dimensions and weight

• Standard IOM slot form factor

• Standard IOM slot form factor

• IOM3-XP weight empty: 4.99 kg (11 lb)

• IOM-1 weight empty: 4.08 kg (9 lb)

Environmental specifications

• Operating temperature: 0°C to 40°C (32°F to 104°F)

• Relative humidity: 15% to 85% (non-condensing)

• Operating altitude: 3048 m (10,000 ft)

Network/element management

• Fully supported by Alcatel-Lucent 5620

• Fully supported by 5620 SAM

Service Aware Manager (SAM)

• Command line interface

• Command line interface

Hardware queues

• Hierarchical service queues: 64,000 –

• Hierarchical service queues: 32,000 – assignable

available to all IOM-attached ports

in 16,000 blocks to each MDA

• Shapers: 64,000 (1-per queue)

• Shapers: 32,000 (1 per queue)

Hardware policers*

• 1 million 2-tier policers

• 16,000

MAC address capacity*

• Up to 2 million 2-tier MAC FIBs

• Up to 128,000 (hardware/software)

Access Control List*

• Up to 174,000 entries per IOM

• Up to 96,000 entries per IOM

• System scaling up to 1.7 million entries

• System scaling up to 96,000 entries

Safety

• EN 60950-1

• IEC 60950-1 CB Scheme

• CSA/UL 60950-1 NRTL

• FDA CDRH 21-CFR 1040

• EN 60825-1

• EN 60825-2

• IEC 60825-1

• IEC 60825-2

EMC

• ICES-003 Class A

• FCC Part 15 Class A

• EN 300 386

• EN 55022

• EN 55024

• EN 61000-4-2

• EN 61000-4-3

• EN 61000-4-4

• EN 61000-4-5

• EN 61000-4-6

• EN 61000-4-11

• IEC CISPR22

• AS/NZS CISPR 22

Immunity

• EN 61000-3-2 Power Line Harmonics

• EN 61000-3-3 Voltage Fluctuations and Flicker

• EN 61000-4-2 ESD

• EN 61000-4-3 Radiated Immunity

• EN 61000-4-4 EFT

• EN 61000-4-5 Surge

• EN 61000-4-6 Low Frequency Common Immunity

• EN 61000-4-11 Voltage Dips and Sags