Installation
510975
30
.
Figure 19
Grounding Instructions
●
The dryer unit must be grounded. In the event of
malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a
path of least resistance for electric current. The
dryer unit is equipped with a cord having an
equipment-grounding conductor and a three-
prong grounding plug. The plug must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
●
DO NOT modify the plug provided with the
dryer unit – if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
●
If the laundry room’s electrical supply does not
meet the above specifications and/or if you are
not sure the laundry room has an effective
ground, have a qualified electrician or your local
electrical utility company check it and correct
any problems.
D799I
1
L1
2
Ground
3
Neutral
4
Round Grounding Prong
5
Neutral Side
D799I
1
2
3
4
5
115 ± 12
V.A.C.
0
V.A.C.
115 ± 12
V.A.C.
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer unit is
properly grounded.
W153
WARNING