beautypg.com

Important safety requirements, Location – AEG 111 K - W/D/G User Manual

Page 14

background image

14

650 mm

420 mm

420 mm

100 mm

50 mm

50 mm

55 mm

600 mm

700 mm

420 mm

100 mm

420 mm

50 mm

55 mm

50 mm

CLEARANCES REQUIRED

WHEN FITTING THE HOB

WITHOUT A COOKER HOOD ABOVE

CLEARANCES REQUIRED
WHEN FITTING THE HOB

WITH A COOKER HOOD ABOVE

FO 0813

FO 0812

700 mm

Important safety requirements

This hob must be installed in accordance with the IEE Wiring
Regulations (Current Edition).
Detailed recommendations are contained in the following British
Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891
Current Editions.

Location

This hob has been registered as a "Class Y" appliance according to Fire
Risk Regulations. Minimum distances detailed below must be observed.
The hob may be located in a kitchen, a kitchen/diner or bed sitting
room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that there is a
minimum distance of 55 mm. between the rear edge of the hob and
the wall. A minimum distance of 100 mm. must be left between the
side edges of the hob and any adjacent cabinets or walls.

The minimum distance combustible material can be fitted above the
hob in line with the edges of the hob is 420 mm. If it is fitted below
420 mm. a space of 50 mm. must be allowed from the edges of the
hob. The minimum distance combustible material can be fitted directly
above the hob is 700 mm.