beautypg.com

Karcher BR 40-25 C Bp Pack User Manual

Page 28

background image

– 12

Faults with display

Battery con-
trol display

Fault indi-
cation

Fault

Remedy

blinks rapidly Excess temperature

in brush drive

Set the program selection switch to
OFF and let the machine cool down.

blinks slowly Cable routing fault,

interruption

Set program switch to OFF. Then se-
lect again the cleaning program. If the
fault recurs, call customer service.

glows

Failure in the elec-
tronics

blinks red fast

blinks rapidly Battery defective

slowly blinks red blinks slowly Overload on brush

motor

Set program switch to OFF. Check
whether foreign matters are blocking
the brushes, remove foreign matter if
required Then select again the clean-
ing program. If the fault recurs, call
customer service.

Faults without display

Fault

Remedy

Appliance cannot be
started

Check battery; charge it, if needed
Check battery pole fuse at the positive pole of the battery (75 A);
inform customer service if the fuse is defective.

Insufficient water quan-
tity

Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.

Insufficient vacuum
performance

Check the condition of the seals between dirt water reservoir and
cover, replace if required.
Clean the fluff filter
Clean the vacuum lips on the vacuum bar, turn or replace if re-
quired
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.

Insufficient cleaning re-
sult

Check the brushes for wear, replace if required.

Brushes do not turn

Check if foreign matters block the brushes; remove foreign matter
if required.

28