beautypg.com

American Dryer Corp. ADG-530D II User Manual

Page 56

background image

52

e. Open main door. The dryer must stop and ALL output indicator lights on the back side of the

microprocessor controller (computer) board must go out. (Refer to the illustration on the previous
page.)

f. Try to restart the dryer with the main door open.

g. The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must read “DOOR.”

h. Close the main door and restart the dryer.

i.

Functional check of microprocessor controller (computer) board is complete.

2. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815

a. Upon completing installation of the

replacement DSI module, reestablish power
to the dryer.

b. Starting the drying cycle.

c. The ignition DSI module’s light emitting diode

(L.E.D.) indicator will light “red” for up to
approximately 1.5-seconds (prepurge time).

d. The module’s indicator light will then turn

“green.” The gas valve will be energized and
the ignitor probe will spark for approximately
8-seconds. The burner flame should now
be
established.

e. With the burner flame on, remove the flame

sensor wire from the FS terminal of the DSI
module.

f. The burner flame must shut off and the ignition

module must lockout with the DSI module’s
indicator light “red.”

g. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module must proceed through the prepurge, with the indicator light “red,” the ignition trial

time of approximately 8-seconds, with the indicator light “green,” and then proceed to lockout with the
indicator light “red.”

i.

Functional check of the DSI module is complete.

1) Replace the flame sensor wire from the FS terminal to the DSI module.

This manual is related to the following products: