Remove lint accumulation from around the openings in the dryer’s back panels.

Remove lint from gas valve burner train area with a vacuum cleaner with brush attachment.

Remove any lint accumulation from the coin acceptor area, including the optical switch.

Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from the dryer’s
internal exhaust ducting.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN

CREATE A POTENTIAL FIRE HAZARD.

WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION

AIR.

Inspect and remove lint accumulation from the dryer’s exhaust ductwork back draft dampers.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of

the heat circuit safety switches and/or thermostats.

6 MONTHS

In the cleaning of the dryer cabinet, avoid using harsh abrasives. A product for the cleaning of appliances is
recommended.

ALL bearings and setscrews should be checked to insure they are tight.

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws (bearing setscrews), grounding connections, nonpermanent gas connections (unions,
shutoff valves, and orifices), and electrical terminals. Tighten loose V-belts when necessary and check the
alignment. Inspect drive motor (impellor/fan) shaft belt. A cracked or seriously frayed belt should be replaced.
Complete operational check of controls and valves. Complete operational check of ALL safety devices (door
switches, lint compartment switches, sail switches, burner and hi-limit thermostats).