beautypg.com

Before startup, Start up – Karcher HD 5-15 C + FR User Manual

Page 17

background image

– 3

If the lever on the trigger gun is released
the pressure switch turns off the pump,
the high pressure jet is stopped. If the
lever is pulled the pump is turned on
again.

The overflow valve and pressure switch
are set and sealed at the factory. Set-
ting only by customer service.

The safety catch on the trigger gun pre-
vents the appliance from being switched on
unintentionally.

Read the oil level display when the de-
vice is not running. The oil level must be
above the two pointers.

Unscrew the fastening screws of the
device hood; remove the device hood.

Cut off tip of oil container cover

Fasten the device hood.

Mount the nozzle on the spray pipe (mark-
ings on the adjustment ring at the top).

Connect ray tube to hand spray gun

Draw the push-handle upwards until the
stop.

Fix the push-handle using the enclosed
screws and tool.

Fasten the high pressure hose to the
high pressure connection.

Insert the crank in the hose drum shaft
and lock it in.

Before rolling up, stretch out the high
pressure hose.

Wind the high pressure hose in uniform
layers on the hose drum by rotating the

crank. Select the rotation direction in
such a way that the high pressure hose
does not get bent.

Lever out the safety clip of the hand
spray gun using a screw-driver (Picture
A).

Place the hand-spray gun upside down
and insert the end of the high pressure
hose till the end. Ensure that the lose
disc falls right below on the hose end
(Picture B).

Press the safety clip back into the hand-
spray gun. The hose can be pulled out
max. 1 mm if it has been installed cor-
rectly. Otherwise, it means the disc has
been installed wrongly (picture C).

Warning

Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. Otherwise, the appliance must
not be used.

For connection values, see technical
data and type plate.

The electrical connections must be
done by an electrician according to IEC
60364-1.

Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.

ƽ

Danger

Danger of injury by electric shock.

The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.

The minimum fuse rating required at the
socket outlet is (see technical specifica-
tions).

Pressure switch

Safety catch

Before Startup

Check oil level

Activate deaeration of oil container

Attaching the Accessories

In devices without hose drum:

In devices without hose drum:

Installing spare high pressure hose

Start up

Electrical connection

17