beautypg.com

Karcher HDS 13-20-4 S EU User Manual

Page 32

background image

– 11

Water shortage

Î

Check water supply, check connections.

The exhaust temperature limiter has
been triggered.

Î

Set the appliance switch to "0/OFF“.

Î

Allow device to cool down.

Î

Turn on the appliance.

Error occurs repeatedly.

Î

Inform Customer Service

Leak in the high pressure system

Î

Check high pressure system and con-
nections for tightness.

Î

Inform Customer Service

The flame sensor turned the burner off.

Î

Inform Customer Service

System care detection defective

Î

Inform Customer Service

Note: Burner can operate 5 more hours.

System care bottle empty.

Î

Replace the system care bottle.

Note: Burner operation no longer possible.

System care bottle empty.

Î

Replace the system care bottle.

No power

Î

Check power connection/conduit.

Air within the system

Vent pump:
Î

Set dosing value for detergent to "0".

Î

With open hand spray gun turn device
on and off multiple times with the device
switch.

Î

Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.

Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
Î

If detergent tank is empty, refill.

Î

Check connections and conduits.

Pressure is set to MIN

Î

Set pressure to MAX.

Sieve in the water connection is dirty

Î

Clean sieve.

Î

Clean the fine filter; replace it, if necessary.

Amount of water supply is too low.

Î

Check water supply level (refer to tech-
nical data).

Water shortage symbol

Burner error symbol

Error symbol

Flame sensor symbol

System care detection symbol

System care symbol

Appliance is not running

Device is not building up pressure

32

EN