Technical specifications, Accessories, Spare parts warranty ce declaration – Karcher IP 120 User Manual
Page 18
18
English
– Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts en-
sures that the appliance can be operat-
ed safely and troublefree.
– At the end of the operating instructions
you will find a selected list of spare parts
that are often required.
– For additional information about spare
parts, please go to the Service section
at www.kaercher.com.
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of your appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication. In the event of a warran-
ty claim please contact your dealer or the
nearest authorized Customer Service cent-
er. Please submit the proof of purchase.
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Alfred Kärcher GmbH Co. KG
Alfred Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Technical specifications
IP 120
IP 220
Electrical connection
Voltage
V
400
400
Current type
3~
3~
Frequency
Hz
50
50
Connected load
kW
4,0
5,6
Maximum allowed net impedance
Ohm
0.147+j0.092
0.169+j0.106
Dry ice
Supply pressure, liquid carbon dioxide
MPa (bar)
1,6...2,1 (16...21)
1,3...2,1 (13...21)
Max. moisture content, liquid carbon dioxide
ppm
66
66
Oil content, liquid carbon dioxide
absolutely free of oil absolutely free of oil
Diameter of dry ice pellets
mm
3
3
Max. pellet production
kg/h
120
220
Feed pressure for liquid carbon dioxide for max. pellet production
MPa (bar)
1,75 (17,5)
1,7 (17)
Dimensions
Width
mm
1320
1560
Depth
mm
700
800
Height
mm
1439
1400
Weight, empty
kg
340
495
Weight, full
kg
360
540
Sound pressure level (EN 60704-1)
dB(A)
85
89
Hydraulic oil as per DIN 51524, part 2
Quality
16/13 as per ISO 4406
Viskosity
ISO VG 32
ISO VG 32
Amount of oil
l
35
60
Accessories
Order No.
CO
2
Detector
6.574-105.0
Scale 600x800 mm with
control
6.574-179.0
Scale 1000x1000 mm with
control
6.574-180.0
Hydraulic oil, 20 l
6.288-223.0
IP 120
Order No.
Extruder plate 16 mm
6.574-060.0
Extruder plate 3 mm
6.574-061.0
Extruder plate 1.7 mm
6.574-200.0
Volume control PCS 120
6.574-181.0
Spare parts package
6.574-175.0
IP 220
Order No.
Extruder plate 16 mm
6.574-002.0
Volume control PCS 220
6.574-178.0
Spare parts package
6.574-176.0
Spare parts
Warranty
CE declaration
Product:
Dry ice pelletiser
Type:
1.574-xxx
Relevant EU Directives
98/37/EC
2006/95/EC
2004/108/EC
Applied harmonized standards
EN 55014–1: 2006
EN 55014–2: 1997 + A1: 2001
EN 626–1
EN 60204–1
EN 61000-3-2: 2006
EN 61000–3–3: 1995 + A1: 2001 + A2:
2005
EN 61000–3–11: 2000
Applied national standards
-
CEO
Head of Approbation