If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
–
If the maximum liquid level is reached
the appliance will turn off automatically.
–
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
–
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.
Plug in the main plug.
Switch on the appliance at the rotating
knob.
The appliance has an innovative dual filter
cleaning system that is particularly effective
with fine dust. The flat pleated filter is auto-
matically cleaned every 7.5 seconds
through an air jet (pulsating sound).
Switch off the appliance at the rotating
knob.
Pull out the mains plug.
Empty the container.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
Loosen the fastening screws of the
pushing handle and adjust the pushing
handle.
Illustration
Store the suction hose and the mains
cable as shown in the illustration.
Place the appliance in a dry room and
secure it from unauthorized use.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance at the handle and at the suction
pipe to transport it.
Hold the appliance at the chassis han-
dle and at the pushing handle when you
want to transport it.
Pull the device behind you at the carry-
ing handle for transporting it over longer
distances
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
General
Clip connection
Operation
Rotating knob
–
Appliance ON
–
Filter dedusting OFF
–
Appliance OFF
–
Appliance ON
–
Filter dedusting ON
Turning on the Appliance
Automatic filter cleaning
Turn off the appliance
After each operation
Fold the push handle in/out
Storing the Appliance
Transport