– 9

Application:

Windows, mirrors

Glass surfaces on showers

other smooth surfaces

Apply steam to the glass surface evenly
with the steam nozzle from a distance
of approximately 20 cm.

Strip the glass surface in straight lines
from the top to the bottom using the rub-
ber lip of the window nozzle. Wipe the
rubber lip and the bottom edge of the
window dry after each strip.

ƽ

Danger

Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.

As limescale builds up in the appliance, we
recommend to descale the appliance in the
following intervals (TF=tank fillings):
Note: If you always use usual commercial
distilled water it is not necessary to descale
the boiler.

Note: Please contact your Conservancy
Board or the local water supply company to
inquire about the hardness of your water.

Disconnect the mains plug from the
socket.

Allow the steam cleaner to cool down.

Remove the nozzle insert from steam
nozzle. To do this, rotate the nozzle in-
sert counter-clockwise with a coin and
pull the nozzle insert out.

Warning

Only use products approved by KÄRCHER
to exclude any damages of the appliance.

Use the KÄRCHER decalcifier sticks
(order no. 6.295-206) to decalcify the
water. Please follow the dosing instruc-
tions on the packaging while using the
decalcifying solution.

Caution
Use caution when filling and emptying the
steam cleaner. The descaling solution can
have an aggressive effect on delicate sur-
faces.

Fill the decalcification solution into the
water tank.

Close the water tank with the tank lid.

Fasten the water tank to the casing.

Press the decalcification pump (A5) for
approx. one minute in regular pump
movements until the decalcification so-
lution escapes from the open steam
nozzle (best over a washbasin).

Loosen, drain and rinse the water tank
with clear water.

Allow the decalcification solution to take
effect in the appliance for 8 hours.

Fill the water tank with fresh water.

Close the water tank with the tank lid.

Fasten the water tank to the casing.

Caution
Do not plug in the mains plug!

Pump the water for one minute with the
decalcification pump through the appli-
ance into a washbasin.

Hold the appliance over a washbasin
and now connect the mains plug.

Warning

Hot water spots – scalding danger!

Press the steam lever and let the appli-
ance evaporate into a washbasin for
two minutes.

Reinstall the nozzle insert into the
steam nozzle and tighten the nozzle in-
sert in a clockwise direction.

The steam cleaner is ready to use.

Squeegee

Maintenance and care

Descaling

Degree of hardness

° dH

mmol/l RF

I

soft

0- 7 0-1,3

35

II medium

7-14

1,3-2,5 30

III hard

14-21 2,5-3,8 20

IV very hard

>21

>3,8

15

Starting the decalcification

Rinsing of the dissolved limescale

15

EN