beautypg.com

Faults – Karcher BD 40-12 C Bp Pack User Manual

Page 24

background image

– 9

Reattach the wastewater tank to the ap-
pliance.

Conect the suction hose with the waste-
water reservoir.

Warning

Charge the battery before commissioning
the machine.

ƽ

Danger

Risk of injury. Before carrying out any tasks
on the device, switch off the button for
brush operations and suction turbine and
pull out the charger plug.

Warning

Risk of damage to the appliance on ac-
count of water leakage. Drain out dirt water
and the remaining free water before work-
ing at the machine.
In case of faults that cannot be remedied
using the table below please contact the
customer service.

The battery status indicator shows the fol-
lowing faults:

Faults

Faults with display

Fault

Remedy

X 1

Power consumption of suction tur-
bine is too high

Turn off the switch for the brush op-
eration; wait briefly and switch it
back on. If the fault recurs, call cus-
tomer service.

X

1

Power consumption the brush drive
is too high

X

1

Suction turbine cable break.

X

1 No disc brush inserted in cleaning

head.
Power consumption of the brush
drive is too low.
Brush drivee cable break.

1 = lights up, X = blinks
Different segments of the battery status indicators are
blinking.

Turn off the switch for the brush op-
eration; release the handle switch
and switch the brush drive switch
back on.

24

EN

This manual is related to the following products: