beautypg.com

ROTHENBERGER Monteurhilfe-Sets User Manual

Page 9

background image

7

Technical data (only for 1690.20 – 1690.30 – 1690.40):


Swept volume:

42 l/min

Ultimate vacuum:

1x10

-2

Power supply:

220-240/1/50-60Hz, 120W

Working temperature:

0 ÷ 50° C

Dimensions RO-Caddy:

520x290x340

Proper usage


These equipments must be used only to perform vacuum and charges in the A/C systems, as declared.

Special safety instructions

It is essential to read and understand the general safety instructions in the Safety appendix

(Page 22 and following)!

Unit is intended for operator professionally well trained, he must know refrigeration fundamentals, cooling
systems, refrigerants and possible damages that equipments under pressure could cause.
Wear safety glasses and gloves when handling refrigerant; avoid contact with refrigerant, blindness and
injuries may result to operator.
Keep away from flames and hot surfaces; high temperature decomposes refrigerant releasing toxic
contaminants very dangerous for environment and operator.
Avoid skin contact; refrigerant has a very low boiling temperature (about -30°C/-22°F) and freezing may
occurs.
Avoid from breathing refrigerant vapour.
Even if the pump temperature is not expected to rise a high level during use, it is advisable to locate the
unit so that users cannot make contact with the casing, as burns may result.
Vacuum pump is air cooled with integral fan; use only where air can freely circulate.
Before station disconnecting, verify cycle has been completed and valves are closed so refrigerant will not
vented in environment.
Do not attempt to fill cylinders with liquid refrigerant more than 75% of total volume.
During operations, do not vent refrigerant in environment. This precaution, also required by international
laws in force for environmental protection, is essential to avoid difficult leaks detection due to ambient
polluted by refrigerant.

A – Overview

1

Low pressure manometer M1

8

capillary tube T3

2

High pressure manometer M2

9

low pressure hose (blue) T1

4

High pressure valve High

10

high pressure hose (red) T2

3

Low pressure valve Low

11

valve low pressure hose V1

5

valve vacuum Vac

12

valve high pressure hose V2

6

valve charge Ref

13

Electronic scale BE

7

valve for the refrigerant bottle V3

trolley

ENGLISH