Improper use may leak liquid from the bottle. Avoid contact with it. If accidental con-
tact happen, read the specific safety instructions.

3. Turn the lever „rinse / ROCLEAN“ in position „ROCLEAN“.
4. Push the „On / Off“ program key. The compressor fills the tank pressure automatically.
5. Open the water supply. Open the pipe system.
6. Push program Key „Water and Air“ (permanently). The chemistry in the bottle is supplied to

the fluid flow through. The process is stopped when the bottle is empty. For larger systems
may are several bottles required (note information on the bottle).

When changing bottles follow the instruction:
– Close pipe system, so that no water flows from the system.
– Push program Key „Water and Air“ (permanently). The compressed air supply is stopped.
– Close water supply.
– Unscrew the empty bottle and replace them with new bottle.

Improper use may leak liquid from the bottle. Avoid contact with it. Note event of
accidental contact, read the specific safety instructions.

– Press program key „water and air (permanently)“.
– Open water supply.
– Open pipe system.
– The chemistry in the bottle is supplied to the fluid flow through. The process is stopped when

the bottle is empty.

– Close pipe system.
– Press program Key „Water and Air“ (permanently). The compressed air supply is stopped.
– The reaction time depends on the degree of soiling or according to the regulation for disin-

fecting drinking water lines. The system must be closed for it.

7. After final rinse cleaning the system until no more chemicals are in the system. Proceed as

follows:

– ROPULS as in „First step - Mechanical cleaning of the system integrate” back into the sys-

tem (if the device has been previously disconnected from the system).

– Move the lever „rinse / ROCLEAN“ position in the „flush“ position.
– Press the „On / Off“ push button. The compressor fills the pressure tank automatically.
– Open water supply, open piping system.
– Push program key „water and air (pulsed)“ button.
– The cleaning process is completed when no more chemicals in the system.
– Turn off the ROPULS.
– Stop the water supply, close ROPULS system and remove.
Third step - preservation of the system (heating circuit):
See steps 1 - 5 of „second-step chemical cleaning“.
8. Push program Key „Water and Air“ (permanently) button. The chemistry in the bottle is sup-

plied to the fluid flow through. The process is stopped when the bottle is empty. For larger
systems required several bottles (note information on the bottle).

When changing bottles proceed as follows:
– Close system, so that no water flows from the system.
– Close water supply.
– Press program Key „Water and Air“ (permanently). The compressed air supply is stopped.
– Unscrew the empty bottle and replace them with new bottle.

Improper use may leak liquid from the bottle. Avoid contact with it. Note event of
accidental contact, read the specific safety instructions.