Troubleshooting
Symptom
Possible Reason
Solution
Machine does not run
No power supply
Check mains power supply
Main switch faulty
Call Customer Service
Motor faulty
Call Customer Service
PRCD switch
Press the RESET button on
the PRCD switch
Screw does not advance when the
feed handle has been operated.
Clamping jaws worn
Replace clamping jaws
Drive belt worn
Replace drive belt
6
Care and Maintenance
Caution: Disconnect mains power supply before carrying out any maintenance!
6.1
Care
The equipment should be handled with care and cleaned regularly.
After every use the screws and tools should be cleaned and treated. We recommend our special
cleaning agent „ROWONAL“(see 7. Accessories). The machine has a lubricating point at the
drive shaft in the area of the clamping jaws, which has to be lubricated using an universal
grease after ten hours operation in each case. In general, all mobile parts in the area for
stressing the clamping jaws are to be lubricated regularly.
6.2
Maintenance and Repair
Important! All maintenance and repair work should only be carried out by
experienced service personnel.
6.3
Replacing the clamping jaws
(B-4)
Dismantle the front cover
Release the two cylinder screws on the front cap
Remove the front cap
Remove the individual clamping jaws and replace by new ones
Install in the reverse order
7
Accessories
Accessory Name
ROTHENBERGER Part Number
Spiral Basket Ø 22 mm x 22.5
No. 72112
Spiral Basket Ø 22, 32 mm x 18
No. 72111
Spiral Guide Hose
No. 72559
Clutch Jaws Ø 22 mm
No. 72561
Clutch Jaws Ø 32 mm
No. 72562
Separating Pin Ø 22, 32 mm
No. 72101
Telescoping Guide Tube Ø 22, 32 mm / 1.9
– 4.3 m
No. 72131
Spiral Retrieving Device
No. 72135