3. Having adjusted the flame to the required low

setting, while the burner is alight, quickly change
the position of the knob from minimum to maximum
and vice versa several times, checking that the
flame does not go out.

4. Some appliances have a safety device

(thermocouple) fitted. If the device fails to work
when the burners are set to the low flame setting,
increase this low flame setting using the adjusting
screw.

5. Once the adjustment has been made, replace the

seals on the by-passes using sealing wax or a
similar substance.

! If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.

! Once this procedure is finished, replace the old
rating sticker with one indicating the new type of gas
used. Stickers are available from any of our Service
Centres.

! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in
order to comply with current national regulations).

Electrical
connections

DATA PLATE

see data plate

This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2002/96/EC and subsequent
amendments.