beautypg.com

Installation – Blodgett KTC-E Series User Manual

Page 8

background image

6

OM-KTT/KTC-E

The KTT/KTC Kettle is provided with complete internal wiring and is ready for

immediate connection. Wiring diagrams are provided in this manual and on the inside

of the control housing service panel. Any mechanical or electrical changes must be

approved by Blodgett’s Engineering Department.

The completed unit has been operated at the factory to test all controls and heater

elements.

1.

Set the kettle in place and level it. The base should be securely fastened to a

table or work surface. Four 3/8”-16 N.C. threaded couplings are provided in the

base of unit. Installation under a ventilation hood is recommended.

2.

Once the unit is anchored to a mounting surface, apply a small bead of silicone

caulk around the perimeter of the kettle base and seal the joint.

3.

Provide electrical power as specified on the electrical information plate

attached to the equipment. Observe local codes and/or The National Electrical

Code in accordance with ANSI/NFPA 70 - (current edition).

4.

Standard equipment is shipped ready for 208V, 3-phase or 480V, 3-phase

operation. Refer to the wiring diagram located on the inside cover of the

control box and the instructions below for conversion to single-phase

operation. A jumper wire and “conversion” label are included with the unit.

They can be found in a plastic bag attached to the trunnion assembly inside

the control box.

a.

For conversion from 208V, 3-phase to 208V or 240V 1-phase or

480V, 3-phase to 480V, 1-phase:

i.

Verify that the branch circuit wiring is adequate for any

increased amperage requirements (see table on page 8).

ii.

For 240V 1-phase only, enlarge electrical inlet opening for

1” conduit fitting. Use a 1” sealtite conduit fitting.

iii.

Refer to wiring diagram for field conversion.

iv.

For 240V 1-phase only, pull lead from 208V tab on control

transformer and insert on 240V tab (See photo on page 8).

v.

Complete “conversion label” (supplied in bag) and adhere it

to the control box near the UL dataplate.

b.

For conversion from 208V, 3-phase to 240V, 3-phase:

i.

Verify that the branch circuit wiring is adequate for any

increased amperage requirements (see table on page 8).

ii.

Pull lead from 208V tab on control transformer and insert

on 240V tab. (See photo on page 8)

iii.

Complete “conversion label” (supplied in bag and adhere it

to the control box near the UL dataplate).

WARNING

INSTALLATION OF THE KETTLE MUST BE

DONE BY A CERTIFIED ELECTRICIAN OR

AUTHORIZED REPRESENTATIVE QUALIFIED

TO WORK WITH ELECTRICITY. IMPROPER

INSTALLATION CAN RESULT IN INJURY TO

PERSONNEL AN/OR DAMAGE

TO EQUIPMENT.

CAUTION

BEFORE ANY ELECTRICAL CONVERSION,

VERIFY THAT THE BRANCH CIRCUIT

WIRING IS ADEQUATE TO HANDLE ANY

INCREASE AMPERAGE REQUIREMENTS.

REFER TO THE ELECTRICAL

SPECIFICATIONS LISTED BELOW.

Installation

This manual is related to the following products: