9.0 TROUBLESHOOTING
BRAISING PAN:
HEATING ELEMENTS DO NOT COME ON:
1.
Power supply not “ON”.
2. Pan not in down position.
3. Defective limit switch.
4. Defective thermostat.
5. Defective elements or loose terminals.
6. Defective contactors.
BRAISING PAN WILL NOT OPERATE (UP OR DOWN):
1.
Power supply not “ON”.
2. Defective UP/DOWN switch.
3. SEE TROUBLESHOOTING - HYDRAULICS (below).
TROUBLESHOOTING - HYDRAULICS:
1) DIRTY OIL:
a) Components not properly cleaned after servicing.
b) Inadequate screening in fill pipe.
c) Air breather left off.
d) Filter dirty or ruptured.
2) FOAMING OIL:
a) Return of tank line not below fluid level.
b) Fluid contamination.
c) Suction leak to pump.