Allied Telesis AT-MC116XL User Manual
Page 31

AT-MC115XL and AT-MC116XL Installation Guide
21
Table 7 Fiber Optic Datalink
Table 8 Fiber Optic Loss Specification (Benchmarks)
Model
Fiber
Type
1
1. MMF = Multimode Fiber.
Fiber
Optic
Diameter
Optical
Wavelength
Minimum
Power/
Link
Budget
Average
Signal
Loss
Maximum
Distance
Spec
2
2. Half-duplex only.
AT-MC115XL
and
AT-MC116XL
MMF
50/125
microns
850 nm
26.40 dB
31.50 dB
300 m
(984 ft)
3
or
2 km
(1.2 mi)
4
3. Operating at 100 Mbps.
4. Operating at 10 Mbps.
MMF
62.5/125
microns
850 nm
36.40 dB
40.0 dB
300 m
(984 ft)
3
or
2 km
(1.2 mi)
4
Fiber
Type
1
1. MMF = Multimode Fiber.
Fiber Optic
Diameter
Optical
Wavelength
Typical Loss
Factor
Worst Case
Loss
Factor
Bandwidth
(Mhz-km)
MMF
50/125 microns
850 nm
3.00 dB/km
3.50 dB/km
400
MMF
62.5/125
microns
850 nm
3.00 dB/km
3.75 dB/km
200
This manual is related to the following products: