beautypg.com

System leds – Allied Telesis Rapier Switch User Manual

Page 10

background image

10

Rapier Switch

C613-04017-01 REV F

System LEDs

System LEDs on its front panel indicate the switch’s operational status.

1. DC models of the Rapier Switch do not have an RPS connector and the RPS LED will not function.
2. Not included on the Rapier 48, G6, G6F-SX/SC, G6F-LX/SC, or G6F-SX/MT-RJ.
3. Hot swapping is supported by Software Release 2.3.1 or later. AT-AR021 (S) BRI-S/T, AT-AR021 (U)

BRI-U, and AT-AR023 SYN PICs can be hot swapped.

The Rapier Switch Hardware Reference has further troubleshooting information,
including information on Switch Port and Uplink Module LEDs.

System LEDs

LED

State

Function

Power

Green

The switch is receiving power and the voltage
is within the acceptable range

Fault

Red

The switch or management software is
malfunctioning

1 flash

A switch fan has failed. (The LEDs will not
indicate an RPS fan failure.)

3 flashes

If an RPS is connected, the switch’s PSU (Power
Supply Unit) has failed

4 flashes

If RPS monitoring is enabled, the RPS PSU has
failed

5 flashes

If RPS monitoring is enabled, an RPS is not
connected or is not operational

RPS

1

(Redundant

Power Supply)

Green

An RPS is connected to the switch

In use

2

(Rear panel)

Green

An NSM is installed, is receiving power, and is
operational. The NSM and its PICs are not
ready to be hot swapped

Off

No NSM is installed, or the NSM is not installed
correctly (the switch unit has not recognised
the NSM)

Swap

2

(Rear panel)

Green

The NSM and its PICs are ready to be hot
swapped

Off

The Hot Swap button must be pressed before
the NSM or PICs can be hot swapped, or the
software release does not support hot
swapping

3