Troubleshooting
To troubleshoot your media converter, perform the following:
1. Set the unit in the Link test Mode.
2. End stations used with the media converter must operate in the same
duplex mode (either both full-duplex or both half-duplex).
3. Verify that the twisted pair cable is Category 5.
4. Verify that proper fiber cable is being used: multimode for the
AT-MC105XL and AT-MC106XL.
5. Verify that the near end node transmitter (TX) is connected to the far end
node receiver (RX) and vice versa on the fiber segment.
Technical Specifications
Table 2 lists the media converter technical specifications
Table 2 Media Converter Technical Specifications
Specifications
Dimensions (W x D x H)
4.125 in x 3.75 in x 1.0 in (10.5 cm x 9.5 cm x 2.5 cm )
Max. Operating temperature
0° C to 40° C (32° F to 104° F)
Max. Storage temperature
-20
o
C to 80
o
C (-4° F to 176° F)
Operating altitude
up to 10,000 ft (3,048 m)
Humidity 5%
to
80%
(noncondensing)
EMI/RFI
meets FCC Class A, EN55022 Class A
Safety
EN60825
EN60950
Immunity
EN50082-1 Immunity Standard
Power
Input supply voltage
Max. current
Power consumption
12 V DC +/-5%
500 mA
6W