beautypg.com

Allied Telesis AT-MCF112VF, SM, LH User Manual

Page 23

background image

AT-MCF106xx and AT-MCF112xx Installation Guide

15

Use a straight-through cable to connect a hub or switch to a twisted
pair port on the unit. Use a crossover cable to connect a workstation to
a twisted pair port on the unit.

Refer to Table 5 for the fiber optic cabling specifications.

Table 5 Fiber Optic Cabling Specifications

Specifications

Media

50/125 micron multimode fiber (MMF)

62.5/125 micron multimode fiber (MMF)

9/125 micron single-mode fiber

1

(SMF)

1

The single-mode fiber optic transmitter is rated as a Class 1 laser.

Maximum Segment
Length - Full-
duplex

Multi-mode fiber: 2 km (1.24 mi)

Single mode fiber: 15 km (9.3 mi)

2

Single mode fiber: 40 km (24.8 mi)

3

2

This applies to the AT-MCF106SM and AT-MCF112SM models only.

3

This applies to the AT-MCF106LH and AT-MCF112LH models only.

Maximum Segment
Length - Half-
duplex

The total distance of all fiber runs cannot exceed the following
limits:

4

With one Media Converter inline:

Switch to Switch = 372 m (1221 ft)

Workstation to Switch = 372 m (1221 ft)

Switch to Class II Repeater = 185 m (607 ft)

Switch to Class I Repeater = 137 m (450 ft)

With two Media Converters inline:

Switch to Switch = 332 m (1089 ft)

Workstation to Switch = 332 m (1089 ft)

Switch to Class II Repeater =145 m (476 ft)

Switch to Class I Repeater = 97 m (318 ft)

4

Each media converter used inline within a single collision domain will reduce the overall segment length by 40 m

(131.24 ft) of fiber.

External Devices

Network Adapter Card, Repeater, Switch, or Router

This manual is related to the following products: