beautypg.com

Fault indicators and what they mean – Allied Telesis AR740 RPS Redundant Power Supply User Manual

Page 6

background image

6

AR740 RPS

C613-04025-01 REV F

Fault Indicators and What They Mean

The LEDs on the rear panel indicate the RPS’s operational status.

If an LED indicates a fault, follow these steps:

1.

Check that all cable connections are correct and secure.

2.

Check that both the RPS and the router are switched ON.

3.

Check that the RPS is receiving the correct AC voltage.

4.

If the LEDs indicate a router fault, verify that the fault exists (check the
router’s fans and LEDs) and, if necessary, replace the router or have it
serviced by authorised service personnel.

If the LEDs still indicate a fault, but no fault exists on the router or power
supply circuits, or if the LEDs indicate an RPS fault, contact your authorised
Allied Telesis distributor or reseller.

LED

State

Function

Power

Green

The RPS unit is receiving AC power and the
voltage is within an acceptable range.

RPS Fan Fault

Amber

The RPS is switched OFF.

Mains power to the RPS has failed.

An RPS fan has failed.

Off

Normal operation.

Main PSU Fault

Amber

The corresponding router is switched OFF or its
PSU has failed.

Mains power to the router has failed.

The DC cable between the router and RPS is not
connected.

The RPS is supplying power to the router.

Off

Normal operation.

RPS PSU Fault

Amber

The RPS is switched OFF or its PSU has failed.

Mains power to the RPS has failed.

The DC cable between the corresponding router
and RPS is not connected.

Off

Normal operation.

Main Fan Fault

Amber

The DC cable between the corresponding router
and RPS is not connected.

A main router fan has failed.

Off

Normal operation.