7.

Carefully slide the expansion module into the slot until the expansion module faceplate
makes contact with the switch, as displayed below. Avoid touching the expansion
module components.

8.

Secure the expansion module to the switch by using a Phillips screwdriver to tighten the
installation screws found on the expansion module faceplate.

Note

Always use the installation screws to secure the expansion module to the switch.
Leaving an expansion module partially seated may cause the system to halt and
subsequently crash.

9.

If you purchased an AT-A47 expansion module, slide the GBIC module into the slot on
the expansion module until it snaps into place, as displayed below.

26

1

3

5

2

4

6

25

10/100/1

000BASE-T

AT-A46

10

100

FULL DU

PLEX

ACTIVITY

LINK

1000

26

1

3

5

2

4

6

25

10/100/1

000B

ASE-T

AT-A46

10

100

FULL DUP

LEX

ACTIVITY

LINK

1000

26

1

3

5

2

4

6

25

1000B

ASE-X

AT-A47

10

ACTIVITY

LINK

CLAS

S 1

LASER

PRODUCT

DO NOT

STARE

INTO B

EAM

10. Connect the twisted pair or fiber optic data cable to the expansion module.

11. Make sure the LINK LED on the front of the expansion module is steady green. (A

1000Base port may require from five to ten seconds to initially establish a link with an
end node.)

LEDs

The expansion modules have port LEDs which display link and activity status on the port.
Refer to the table below for port LED information.

LED

State

Description

AT-A45/xx Series Expansion Modules

LINK

Steady Green

The port has established a valid link with the end
node.

Flashing Green

The port is transmitting and/or receiving data.

DUPLEX

Steady Green

The port is operating in full-duplex.

Steady Amber

The port is operating in half-duplex.

Flashing Amber

Collisions are occurring on the port.

AT-A46 Expansion Module

LINK 10

Steady Green

The port has established a valid
10 Mbps link with the end node.

LINK 100

Steady Green

The port has established a valid
100 Mbps link with the end node.

Both LINK 10
and LINK 100

Steady Green

The port has established a valid
1000 Mbps link with the end node.

FULL DUPLEX

Steady Green

The port is operating in full-duplex.

OFF

The port is operating in half-duplex.

ACTIVITY

Flashing Green

The port is transmitting and/or receiving data.

AT-A47 Expansion Module

LINK

Steady Green

The port has established a valid 1000 Mbps link
with the end node.

ACTIVITY

Flashing Green

The port is transmitting and/or receiving data.

26

1

3

5

2

4

6

25

10/100/1

000B

ASE-T

AT-A46

10

100

FULL D

UPLEX

ACTIVITY

LINK

1000

Port Specifications

The table below provides port specifications for the AT-A45/MT and AT-A45/SC expansion
modules.

Technical Specifications

Maximum Operating Temperature:

0° C to 40° C (32° F to 104° F)

Maximum Storage Temperature:

-20° C to 80° C (-4° F to 176° F)

Operating and Storage Altitude:

Up to 3,048 meters (10,000 feet)

Relative Humidity Operating

and Storage:

5% to 80% (non-condensing)

EMC:

FCC Class A, EN55022 Class A, EN55024

Safety:

EN60825, EN60950, UL1950 (UL/cUL)

Electrical Safety and Emission Statement

Standards: This product meets the following standards.

Emission

FCC Class A, EN55022 Class A, VCCI Class A

WARNING:

In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.

Immunity

EN50082-1

Electrical Safety UL1950 (UL/cUL), EN60950 (TUV)

Copyright

 2003 Allied Telesyn, Inc. All rights reserved.

No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.

Pin

Signal

Operating Wavelength

1310 nm

Transmitter Output Power

50/125 µm cabling
Min: -22.5 dBm avg.
Max: -14 dBm avg.
62.5/125 µm cabling
Min: -19 dBm avg.
Max: -14 dBm avg.

Receiver Sensitivity

Max: -14 dBm avg.

U.S. Federal Communications Commission

RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.

Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.

Industry Canada

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.

4

5

6

This manual is related to the following products: