2. Technical Gas Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ------------ 3/4-inch N.P.T.
Inlet supply size ------------ 3/4-inch N.P.T. (minimum)
Btu/hr input (per dryer) --- 200,000
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column
(W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. (liquid propane) gas have the gas valve's internal pressure regulator
blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure
measured at each gas valve pressure tap must be a consistent 10.5 inches water column (W.C.).
There is no regulator or regulation provided in an L.P. dryer. The water column (W.C.) pressure must
be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
* D.M.S. (Drill Material Size of equivalents are as follows:)
Natural Gas ................... #29 = .1360"
Liquid Propane Gas ....... #47 = .0785"