SPECIAL APPLICATION

400-0210-001

10

7. [IN]

This command is used to select the PE1004CF
input that will be directed to the plasma display’s
active expansion input.

Command Format: [INnCi]

n

= Input Number (n = 1, 2, 3 or 4)

Ci = Unit ID (i = # from 0 to 99)

Example:

Output the PE1004C’s CAT-5 #2 input to the
plasma display input number 3. First, set the
plasma to expansion input three. Then send the
command [IN2] to output the PE1004CF’s
CAT-5 #2 input to the plasma monitor.

REMEMBER: When an expansion input is

selected on the monitor, its
corresponding PE1004CF input is
selected automatically.

8. [EQn]

This command is used to set the amount of
video equalization when software equalization is
selected, and to make it active for adjustments
using the [+] and [ - ] commands.

Command Format: [EQnCi]

n

= Equalization amount (n = # from 0 to 254)

Ci = Unit ID (i = # from 0 to 99)

Example:

Set the video equalization level to 150 by
sending the command [EQ150].

9. [EQ]

This command displays the current level of
software equalization and makes it active for
adjustments using the [+] and [ - ] commands.

Command Format: [EQCi]

Ci = Unit ID (i = # from 0 to 99)

Example:

Check the video equalization level to by sending
the command [EQ]. The system will return the
following feedback for the previous example:

150

10. [ + ]

This command increments a selected property,
in this case equalization, to be adjusted using
RS-232 control.

Command Format: [ + ], [+k]

[+] = Increment level by one-step

[+k] = Increment level by 'k' steps

Example:

Select the equalization command by sending
the command [EQ]. The current level is 150, but
it is not the optimal value. After sending the
following commands, an optimum level of 160 is
obtained:

1.

[EQ]

The current level is 10.

2.

[+][+][+][+][+][+][+][+][+][+] or [ + 10 ]

The level is now 160 and no further

adjustments are required.

11. [ - ]

This command decrements a selected property,
in this case equalization, to be adjusted using
RS-232 control.

Command Format: [ - ], [-k]

[-] = Decrement level by one-step

[-k] = Decrement level by 'k' steps

Example:

Select the equalization command by sending
the command [EQ]. The current level is 160, but
it is not the optimal value. After sending the
following commands, an optimum level of 140 is
obtained:

1.

[EQ]

The current level is 160.

2.

[ ] [ ] [ ] … [ ] or [20]

The level is now 140 and is no further

adjustments are required.