Alignment and adjustments, Error items and diagnostic codes, Warning – Samsung DV361GWBEWR-A3 User Manual
Page 2

2
ERROR ITEMS AND DIAGNOSTIC CODES
An occurrence of an Error will make a sound of error melody for 5 sec and continuously show one
of the Error Displays from the following errors.
Error Display
Trigger
Action Taken
tE
The Termistor resistance is very low
or high.
Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.
hE
HE
Invalid heating Temp in running the
dryer
Check for:
- Restricted vent system.
- Check Thermistor resistance.
do
dE
Running the dryer with door open
Check for:
- Close the door, and run the dryer
- Loose or open wire terminals in
Door Sense circuit.
dF
Invalid door state for more than
256 milliseconds
Check for:
- Loose or open wire terminals in
Door Sense circuit.
bE
bE2
Invalid state of key circuit short for
30 secs(all models)
Check for:
- Display PCB key circuit short or not
FE
Invalid power source Frequency
Check for:
- Not using regular power source
frequency
- Invalid power frequency sense
circuit
Et
Invalid state of Eeprom
communication
Check for :
- PCB with Eeprom circuit.
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Technical_information-02365J-01_EN.indd 2
2012-09-11 �� 3:09:09