Trouble shooting, Warning, Sensor bars & temperature sensor check – Samsung DV361GWBEWR-A3 User Manual
Page 10
![background image](/manuals/421227/10/background.png)
10
Steam Models Only
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
CN1
1. AC Power Port
2. AC Power Off Detection
Sensor
3. Door Detection Sensor
RY5
-
Motor Relay Switch
RY6
- Heater Relay Switch
Sensor Bars & temperature sensor check
Sensor Bars - Disconnect harness and test Pink
wire Pin 4 to Orange wire Pin 5.
Approx ∞ Ω without laundry
Approx 190Ω ± 10% with wet clothes
Cycling Thermostat - Disconnect harness and test
Blue wire Pin 2 to Red wire Pin 6.
Approx 10 KΩ at 25 °C/77 °F
Technical_information-02365J-01_EN.indd 10
2012-09-11 �� 3:09:11
This manual is related to the following products: