12) “Flame” (Burner Control Failure) input L.E.D. indicator

13) “Power Supply”

e. Open main door. The dryer must stop and ALL indicator dots of the microprocessor (computer) L.E.D.

(light emitting diode) display must go out. (Refer to illustration on page 37.)

f. Try to restart the dryer with the main door open.

g. The microprocessor (computer) board’s L.E.D. display must read “MAIN dOOR

h. Close the main door and restart the dryer.

i. Functional check of microprocessor (computer) board is complete.

2. Hot Surface Ignition (HSI) System

a. Upon completing installation of the

replacement Hot Surface Ignition

(HSI) module, reestablish power to

the dryer.

b. The HSI module’s “red” indicator

light will light for up to approximately

5-seconds (self check routine).

If the HSI module’s “red” indicator

light stays on or flashes continuously,

then the HSI module is wired

incorrectly or has failed.

c. Start the drying cycle.

d. The hot surface ignitor will turn on, and a few seconds later the gas valve will be energized. After

approximately 4-seconds the hot surface ignitor will shut off. Ignition (flame) should now be established.

e. With the burner flame on, remove the flame sensor wire from the S2 terminal of the HSI module. The

burner flame must shut off immediately.

f. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

g. The hot surface ignitor will turn on, and after a few seconds later the gas valve will be energized and the

hot surface ignitor will shut off. Ignition (flame) should be evident for approximately 7-seconds and

then shut off.

h. The HSI module will attempt two (2) additional ignition trials after which the HSI module will lockout and

the “red” indicator light will flash continuously.

i. Functional check of the Hot Surface Ignition (HSI) Module is complete.

1) Replace the flame sensor wire from the S2 terminal to the HSI module.