AdderView MATRIX MP

Installation and Use

Page 58

USERS

ADMIN

Alan

Jim

Sue

Test

PASSWORDS

password

letmein

hello

logmein

Test

COMPUTERS

PORT

Admin PC

2103

1

1

1

1

Alan's System

2102

1

1

1

Comms Server

3

1

1

Comms PC

4

1

1

1

1

Gateway 1

8

1

Gateway 2

5

1

Test System

15

1

1

Web Browser

9

1

1

1

To restore the saved / edited menu and configuration settings:

1. Connect the serial port on the rear of the AdderView MATRIX MP to a serial

COM port on your computer using the serial cable supplied with the AdderView.

2. Copy the program AVMWRITE and AVMDATA.CSV into the same directory on

the PC that is connected to the AdderView’s serial port.

3. Run the program AVMWRITE.EXE and follow the instructions given by the

program.

4. Make sure that you are logged onto the AdderView as the ADMIN user. From the

main selection screen press F1 for

More Menus. In the Configuration Menu

select

Functions. In the Functions menu select Read Data from RS232 port.

5. The AdderView should then receive the configuration data to your computer and

load the new menu names and access rights into the menu.

4.20 Switching channels by sending RS232 data

You can switch the AdderView MATRIX MP remotely by sending RS232 data to the
serial communications port (located on the rear panel adjacent to the power
connectors). All data should be sent using the following RS232 protocol.

Baud: 19200, bits: 8, stopbits: 1, parity:none