beautypg.com

Ba ba0 0, 44ba ba – Adder Technology AVM208MP User Manual

Page 56

background image

AdderView MATRIX MP

Installation and Use

Page 55

Although it is theoretically possible to select computers on cascaded units by
pressing the hotkeys and then typing in the port address this would be highly
confusing for users and is not generally recommended. Consequently it is normally
advisable to use the on-screen menu to select computers on cascaded units.

However it is sometimes useful to be able to connect to ports on cascaded units via
a specific cascade cable (rather than the first available of a group) in order to check
that the cabling is working as expected. To do this you can use a hotkey sequence
similar to the example shown below.

For example to connect to port 14 on a AdderView MATRIX MP that is cascaded off
port 1 of your first AdderView MATRIX MP. Although the following example selects a
port with a four digit address (port 0114) you can type port addresses that are eight
digits long to access computers that are on the forth cascade level (e.g. Port
01140203).

press

ba

ba0

0

release

0

0

press

1

1

release

1

1

press

1

1

release

1

1

press

4

4

release

4

4ba

ba

4.16 Resetting user port keyboards and mice

The user port keyboards and mice may be reset by disconnecting then reconnecting
the device. You may also disconnect devices and reconnect different devices.