Troubleshooting (cont’d), Diagnosing faults, Diagnostic led flash fault descriptions – Wesley Pack Mule User Manual
Page 26: Calibrator fault identifi cation codes

26
EUV Owner’s Manual 2 May 22, 2009
Troubleshooting (cont’d)
Diagnosing Faults
The controller includes a number of features designed to help the user track down operational, wiring, or
internal controller faults. The diagnostic LED mounted next to the calibrator connectors on the front of the
controller serves as a simple diagnostic tool. Use the table below to identify faults. Faults are cleared by
re-initiating the start sequence.
Diagnostic LED Flash Fault Descriptions
LED Display
Description
ON
No fault, normal conditions
OFF
Internal controller fault
1 Flash
Personality out of range
2 Flashes
Illegal start condition (Traction)
3 Flashes
MOSFET Short circuit
4 Flashes
Contactor fault or motor open circuit
5 Flashes
Motor stalled
6 Flashes
Accelerator wire off fault
7 Flashes
Low or high battery voltage or BDI cutout operating
8 Flashes
Over temperature or timed cutback
9 Flashes
Internal monitor function tripped / Maintenance required
10 Flashes
Power up autozero has not been completed
Calibrator Fault Identifi cation Codes
In addition to the LED indication, a more detailed description of the fault may be found by using the
calibrator. Menu item 13.01 gives a fault identifi cation code which further defi nes the detected fault. The
following table lists the fault ID codes.
ID Code
Fault Name
Flash Fault
0
NO_FAULT
LED_ON
1
UNIT_TOO_HOT
8
2
MONITOR_TRIPPED
11
3
I2T_CURRENT_LIMIT
8
4
MOTOR_TOO_HOT
12
5
MAINTENANCE_CLOSE_FAULT
9
6
ACCELERATOR_FAULT
6
7
ACCELERATOR_POWER_UP_FAULT
6