Raven100 CDMA AirLink Cellular Modem

1. Modem name: A unique name for the modem (the 10-digit MDN number

is recommended).

2. Domain: The domain name to be used by the modem (eairlink.com).

3. IP Manager IP Address: The IP or domain name of the dynamic DNS

server which is running IP Manager (eairlink.com).

4. IP Manager update interval: How often you want the address sent to IP

Manager. If this is set to zero, the modem will only send an update if the
IP changes (i.e. if the modem is reset or is assigned a different IP).

Restrictions for Modem Name

• Must begin with a letter or number

• Can include a hyphen (-)

• Cannot contain spaces

• Must be no longer than 20 characters total

Click the Write icon to save the changes

.

Click the Reset icon to restart the modem.

Click the Disconnect icon to terminate communications with the modem.

6. LoggerNet/PC400W Software Setup

The Device Map is configured from the “Setup” button on the
LoggerNet/PC400W Toolbar. Configure the Device Map as described below.

1. Selet Add Root | IPPort.

2. Add a datalogger to the IPPort (Pakbus dataloggers, e.g. the CR1000,

require a PakBusPort).

3. On the IPPort page, add the IP address/domain name and the Port number

(the Raven template file configures the port to be 3001).

4. For PakBus dataloggers, leave the default settings on the PakBusPort page

(Extra Response Time may be needed).

5. For PakBus dataloggers, set the PakBus address to match that of the

datalogger (default address in the datalogger is 1).