4. Wiring

The NR-LITE can be measured with a differential or single-ended channel on
the datalogger; a differential channel is recommended.

White Radiation

Signal

Green Signal

Reference

Clear

Shield

(User supplied jumper wire for differential measurement only)

FIGURE 7. NR-Lite to Datalogger Connections

TABLE 1. Datalogger Connections for Differential Measurement




Function




Color




CR10X,CR510



CR23X,

21X, CR7

CR800,
CR850,

CR1000,
CR3000,

CR5000

Radiation Signal

White

Differential H

Differential H Differential

H

Signal Reference

Green

Differential L

Differential L

Differential L

Jumper

to

AG

Shield Clear G

TABLE 2. Datalogger Connections for Single-Ended Measurement




Function




Color




CR10X,CR510



CR23X,

21X, CR7

CR800,
CR850,

CR1000,
CR3000,

CR5000

Radiation Signal

White

S.E. Channel

S.E. Channel

S.E. Channel

Signal Reference

Green

AG

Shield Clear G