Campbell Scientific Getting Started Quickstart Guide User Manual
Page 2

4
5
6
7
8
9
10
11
12
Open the Short Cut datalogger program creation software. In LoggerNet,
Short Cut is found under Program. In PC200W and PC400, Short Cut is
found in the Tools menu (or clicking on the red ‘clock’ icon).
• Use Short Cut to generate a basic datalogger program for all
the sensors that will be attached to the datalogger.
NOTE: Video tutorials covering datalogger programming and other
topics relevant to Campbell Scientific products are available at:
www.youtube.com/user/CampbellScientific
Follow the wiring diagram created by Short Cut to attach the sensors to the
datalogger. The wiring must match the diagram exactly for the sensors to
be measured correctly.
Use PC200W, PC400, LoggerNet, or RTDAQ to send the program to the
datalogger. Connect to the datalogger and view the real-time sensor
measurements in the Public table.
• Are the sensors making good measurements?
• If any sensor is not reading as expected, change the sensor
setting in Short Cut and repeat steps 6–7. Also verify that all
sensors wires are properly wired to the datalogger.
After giving the datalogger sufficient time to take multiple measurements,
collect and review the data.
• Are the data values within the range of what is expected for
each sensor?
• Are the records being stored correctly to the data table(s) and
at the desired interval?
• If the data will be post-processed, is it in a file format that can
be used?
• Do the data values provide the information expected?
[Optional] Using the CRBasic Editor (not available in PC200W), expand the
program for any need beyond the basic Short Cut program. Take the time
to add comments to the program to explain.
Make an archival copy of the program and wiring diagram by saving them
to a second computer or storage device. Printing a hard copy to place in
the enclosure is also recommended.
Connect any communication devices to the datalogger.
• Configure and test each communication device.
• Refer to the device's manual on the ResourceDVD for additional
information.
• If using LoggerNet, use Network Planner to assist in the
configuration of each device. The Network Planner is in the
LoggerNet Launch | Tools category. Alternatively, use the
Device Configuration Utility (found on the Resource DVD) to set
up the device as indicated in the user manual.
Before deploying the system in the field, assemble the system as much
as possible. Note what tools and hardware are needed to complete the
assembly. Make sure these tools and hardware are available for final
assembly in the field.
Deploy the system in the field and test by repeating steps 5–7 to confirm
the system is functioning.
Short Cut
13
Campbell Scientific resources on the internet.
Manuals: Support
Videos:
https://www.campbellsci.com/manuals
https://www.youtube.com/user/CampbellScientific