8 | SAMLEX AMERICA INC.

inStallation conFigurationS

general

This Transfer Switch has been especially pre-wired for ease of connections for setting up
a backup power / UPS (Un-interruptible Power Supply) system comprising of an Inverter,
a battery charger and batteries. A backup power system / UPS can be used in on-grid,
off-grid and rV applications. General overview and features for the pre-wired configu-
ration are given below:

- Primary AC power of up to 3600 VA (30A at 120 VAC) can be provided by electric

utility (also called Shore Power Cord or “Cord” in rVs). This is connected to the
Normally open Contacts T3 and T4. NeMA-20r Duplex receptacle (3, fig. 1) has
been provided on the side of the unit for ease of connecting the NeMA5-15P or
NeMA5-20P plug of a battery charger.

- back-up power of up to 3600 VA (30A at 120 VAC) can be provided from an in-

verter. A 15A power cord (1, fig 1) with a 15A, NeMA5-15P plug (2, fig. 1) has been
provided to allow easy, pluggable connection to inverter of up to 1800 VA capacity.
for connecting higher capacity inverter > 1800A & up to 3600 VA, replace the
wiring with AWG#10/3 and connection arrangement rated for 120 VAC, 30A.

Switching between utility/Shore power cord (rV) & inverter

(please see Fig. 1, 2 and 4)

Fig.4. Switching Between Utility and Inverter

SecTIOn 3 |

Installation

ON

LED1

TERMINALS:

T1 LINE “L”, COMMON

T2 NEUTRAL “N”, COMMON

T3 LINE “L1”, NO
(NORMALLY OPEN)

T4 NEUTRAL “N1”, NO
(NORMALLY OPEN)

T5 LINE “L2”, NC
(NORMALLY CLOSED)

T6 NEUTRAL “N2”, NC
(NORMALLY CLOSED)

T7 (–) INPUT FOR RELAY COIL

T8 (+) INPUT FOR RELAY COIL

T5

T7

T8

T1

T2

T3

20A

FUSE

BATTERY

SIDE FUSE

FOR

INVERTER

BATTERY SIDE

FUSE FOR

CHARGER

INPUT FROM INVERTER

TO NORMALLY CLOSED (NC)

CONTACT TERMINALS T5,T6

OUTPUT TO

AC BREAKER

PANEL

DISCONNECT

THE CONVERTER

EXISITING ON-BOARD

CONVERTER

30 A MAIN

BREAKER PANEL

FIG 4 30 A SYSTEM FOR ALTERNATE SOURCE / INVERTER

INPUT FROM

ELECTRIC UTILITY / SHORE

POWER CORD (RV)

TO NORMALLY OPEN (NO)

CONTACT TERMINALS T3,T

4

30

MAIN

BRANCH CIRCUITS

CONVERTER

1 2 3 4 5

BATTERY

CHARGER

BATTERY

+

+

INVERTER

+

+

T4

T6

SW1

TO BATTERY

+

NEMA5-20R DUPLEX

RECEPTACLE