Flytec 3010 User Manual
Page 2
Seite 2 von 2
Vario sound: Sound can either be switched off entirely or 2 volume levels can be set by repeatedly pressing the volume key (8). The volume level currently
set will sound when the key is pressed.
When the unit is switched on, the volume is automatically set at level 1.
Ascent tone: A sound interval with a rising tone frequency dependent on ascent frequency and a timbre dependent on scale (ASI: Acoustic Scale
Indication). The response point is set to optimum response time (factory setting) and can be altered by means of a regulator inside the unit (please consult
a specialist).
Descent tone / descent alarm: A continuous falling tone frequency de pendent on descent with a timbre dependent on scale (ASI: Acoustic Scale
Indication).
Can be switched on or off by pressing the descent tone key (9). On switch ing on the descent tone/alarm and pressing the key, a segment will appear in the
descent sector of the vario display to indicate the current response point. When the descent tone/alarm is switched off, pressing the key will not produce
a display. The descent tone/alarm will only sound when the vario acoustic facility is switched on.
When the descent tone key (9) is pressed for approx. 3 seconds, the unit moves into the adjustment mode for descent tone/alarm (see Setting mo de). The
response point can be adjusted within the fi rst sector of the scale.
Wind speed display: The vane wheel sensor is connected to the socket (6) on the left-hand side of the unit. The display replaces the digital vario display
(3) and is shown by means of the indicator over the display. This display is used to measure start winds.
Peak value memory: Pressing the MEMO key (11) will display the peak values (max. absolute altitude 2 and maximum ascent) of the current fl ight (F0).
Pressing the reset key UP (7) or DOWN (8) will invoke the peak values of the last four fl ights (F1, F2, F3 and F4), with fl ight 4 (F4) the least recent fl ight.
Flight data is saved automatically when the unit is switched off (condition: the unit must have been switched on for 3 minutes and there must have been
a clear difference in altitude).
Memories FI to F4 are updated and the data of the least recent fl ight is deleted.
Battery change: Unscrew the unit and open up the back. Use a 9 V battery.
Changeover to rechargeable battery operation: Order the FLYTEC AKKU SET from your local dealer (2 rechargeable batteries and 1 charging unit) .
N.B. Only use rechargeable batteries ! The charging unit must never be connected when non-rechargeable batteries are being used.
Water damage: Open the unit immediately. lf salt water has entered the unit, rinse it thoroughly (the printed circuit board, in particular) with hand-hot fresh
water. Allow the unit to dry as well as possible, preferably in the sun. lf this is not possible, the unit must be placed on a piece of wood in an oven. Allow the
unit to dry off for one or two hours as required, at a temperature of approx. 50ºC. Leave the oven door open slightly to allow any moisture to escape!
N.B. Never put the unit in a microwove oven !
Attachment: Clip or special attachment for hang-glider (fi t to the rear of the unit). The clip can be unscrewed, rotated 90º and refi tted.
Adjusting the security cord: Open the unit, cut the cord to the required length and knot it well. Tighten the cord from the outside and screw the unit
together again.
Servicing, repairs: Return the unit to your nearest FLYTEC service agent.
FLYTEC AG,
Ebenaustrasse 8, CH-6048 Horw,
Telefon: 041 / 340 34 24,
Telefax: 041 / 340 54 24