The air shutter is located on the back end of the broil
burner. It is attached to the top of the oven cavity with 7
screws. Remove screws and gently pull broil burner
assembly straight out being careful not to detach electrical
wires. Place broil burner against back wall of oven cavity.
Loosen screw and turn shutter. Close the shutter if the
flame is lifting or blowing or not carrying over. Open the
shutter if it is too yellow (see Figure 8). Tighten screw.
Replace broil assembly being careful to feed all wires
through the back of the oven. Reinsert all 7 screws.
Note: The air shutter on the broil burner fits over the
orifice when installed correctly.
Adjust Broil Burner Air Shutter
(if necessary)
Figure 8
Allow Burner(s) to cool before
attempting to remove them!
The oven burner air shutter is located near the oven
regulator. Reach it through the access hole in the
interior back panel of the warming drawer (loosen
screws and remove access panel). Loosen screw on
shutter. Close the shutter if the flame is lifting or
blowing or not carrying over; Open the shutter if it is
too yellow. Tighten screw. Reattach cover plate and
replace warming drawer (see Figure 9).
Adjust Bake Burner Air Shutter
(if necessary)
Step 6: Final Steps - Adjust the Flame (if necessary)
WARNING:
Shutter Screw
More Open:
•Less Yellow Flame
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or
blowing
Figure 9
Shutter
More Open:
•Less Yellow
Flame
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or
blowing
Replacement Parts: Visit your Siemens dealer for replacement parts. For a dealer near you contact Siemens Service
866-44SIEMENS (447-4363).