beautypg.com

Rinsing the iron steam chamber, Cleaning & maintenance, Calc‘n clean – Siemens TS20XTRM2 User Manual

Page 18

background image

18

SIEMENS

ENGLISH

F

Rinsing the iron steam

chamber

Caution! Risk of burns!

This procedure helps to remove scale particles

out of the steam chamber.

This cleaning procedure may be performed

occasionally (approximately once a year), when

after a long period of use with very hard water,

scale particles start to come out of the soleplate.

a) Ensure that the iron is cooled down.

b) Set the temperature selector (15) of the iron to

the “min” position.

c) Fill the tank with tap water.

d) Plug in the mains cable and set the main

power switch (13) to the “I” position.

e) Wait until the “steam ready” indicator lamp (9)

lights up.

f) If the steam station has steam regulator (11*),

set it to the maximum position .

g) Hold the iron over the sink or a container to

collect the water.

h) Press the steam release button (16) and gently

shake the iron. Boiling water and steam will

come out, carrying scale and or deposits that

might be there. This could take approximately 5

minutes.

i) Set the temperature selector (15) of the iron to

the “max” position, without pressing the steam

release button (16). The water in the steam

chamber will start evaporating. Wait until all the

water inside the chamber has been evaporated.

j) To clean the soleplate, immediately rub off any

residue by running the hot iron over dry cotton

cloth.

Cleaning &

Maintenance

Always unplug the appliance from the mains

supply before carrying out any cleaning or

maintenance operation on it.

1. After ironing, pull out the plug and allow the

appliance to cool down before cleaning.

2. Wipe the housing, handle and iron body with a

damp cloth.

3. If the soleplate is soiled with dirt or scale,

clean it with a damp cloth.

4. Never use abrasive products or solvents.

E

“Calc‘n clean”

Cleaning the Boiler

To extend the life of your steam generator and to

avoid any build up of scale, it is essential that you

rinse out the boiler after several hours of use

(approximately after 50 hours). If the water is

hard, increase the frequency.

Do not use descaling agents for rinsing out the

boiler, as they could damage it.

1. Check that the appliance is cold and unplugged

for more than 2 hours, and that the water tank

(1) is empty.

2. Place your appliance on the edge of your

kitchen sink.

3. Remove the plastic cover located on the

bottom of the appliance by turning it to the

position.

4. Unscrew the boiler drainage plug using a coin.

5. Holding your steam generator in upside down

position, and using a jug, fill the boiler (in the

base unit) with 1/4 litre of water

6. Shake the base unit for a few moments and

then empty it completely over a sink or bucket.

To obtain the best result, we recommend that

this operation is done twice.

Important: before re-closing, make sure no

water remains in the boiler.

7. Replace and tighten up the boiler drainage plug

with a coin.

8. Insert and close the plastic cover by turning it

to the position.

Automatic clean warning

(depending on model)

Pilot light (12*) will flash indicating that boiler

must be rinsed. To do this, follow the procedure

described in the section above.

To reset “Calc‘n clean” pilot light and counter,

switch the station off twice, keeping it off

during at least 30 seconds each time.

(on → 30s off → on → 30s off → on)