Problem

Possible causes

Solution

The display does not

react when touched.

• Dirt on the display.

• Fingers too cold.

• Clean the display with a damp cotton

fabric (not too wet).

• Warm your fingers a little bit and try

again.

” icon flashes

• The steam release button (13) on

the iron handle has not been

pressed during the last 8 minutes,

and the auto shut-off system has

been activated.

• Press the steam release button again to

switch the steam station back on.

icon flashes.

• Water tank is empty and must be

filled.

• Fill the water tank.

” icon flashes.

• Boiler and filter must be rinsed.

• Rinse the filter and the boiler according to

the cleaning instructions in this manual

(see section F).

When touching the

display, the beep

cannot be heard.

• The beep has been deactivated.

• Activate it according to instructions in this

manual.

The steam generator

does not come on.

• There is a connection problem.

• The main power button is not

switched on.

• Check the mains cable (5), the plug and

the socket.

• Set the main power button (9) to the “I”

position (illuminated in red).

The iron does not heat

up.

• The main power button is not

switched on.

• The temperature is set to a low

position.

• Set the main power button (9) to the “I”

position (illuminated in red).

• Set the temperature to the desired

position.

The iron begins to

smoke when switched

on.

• During first use: certain

components on the appliance have

been lightly greased at the factory

and may produce a little smoke

when initially heated.

• During subsequent use: the

soleplate may be soiled.

• This is completely normal and will stop

after a short while.

• Clean the soleplate according to the

cleaning instructions in this manual.

Water flows through the

holes on the soleplate.

• The steam function is being used

before it has reached the correct

temperature.

• The water is condensing inside the

pipes because steam is being used

for the first time or has not been

used for a long time.

• The steam generator contains too

much scale.

• Reduce the steam flow when ironing at

low temperatures.

• Point the iron away from the ironing area

and press the steam release button until

steam is produced.

• Clean the boiler as described in section

“calc’nClean Plus” (F).

Dirt comes out through

the soleplate.

• There is a build up of scale or

minerals in the steam tank.

• Chemical products or additives

have been used.

• Use tap water mixed 50% with distilled or

demineralised water. To prolong the

optimum steam function, mix tap water

with distilled water 1:1. If the tap water in

your district is very hard, mix tap water

with distilled water 1:2.

• Clean the soleplate with a damp cloth.

• Never add products to the water.

The iron does not

produce any steam.

• The boiler is not switched on or the

water tank is empty.

• The steam regulation is set to the

minimum position.

• Set the main power button (9) to the “I”

position (illuminated in red), and/or fill the

water tank.

• Increase the steam flow (see section C).