beautypg.com

7 appendix: specifications and options, 1 specifications – Matrix Orbital LCD/VFD Legacy User Manual

Page 29

background image

Command

Syntax

Default

Notes

Read Version Number

FE 36

254 54

254 ’6’

Reads

the

firmware

ver-

sion

number

of the module.

Returns a 1-byte

value.

Enter flow control mode

FE 3A [full] [empty]

254 58 [full] [empty]

254 ’:’ [full] [empty]

off

Sets "full" and

"empty"

marks

for the 80 byte

display

buffer.

When

buffer

reaches

[full]

display

will

return 0xFE to

host.

When

buffer

reaches

[empty] display

will return 0xFF.

Exit flow control mode

FE 3B

254 59

254 ’;’

Turns off flow

control.

7 Appendix: Specifications and Options

7.1 Specifications

Table 20: Environmental Specifications

Standard Temperature

Extended Temperature

Operating Temperature

0

C to +50

C

-20

C to +70

C

Storage Temperature

-20

C to +70

C

-40

C to +85

C

Operating Relative Humidity

90% max non-condensing 90% max non-condensing

Table 21: Electrical Specifications

Supply Voltage

4.75 - 5.25 Vdc (optional 7 - 35 Vdc)

Supply Current

10 mA typical

Supply Backlight Current

115 mA typical

Matrix Orbital

LCD4041

26