beautypg.com

3 general purpose outputs – Matrix Orbital VK204-25 Legacy User Manual

Page 13

background image

/ write bit. If we take a standard Phillips 7bit address of 45hex this would be in binary 1000101. This is

7bits. Matrix Orbital would describe the Phillips I

2

C address of 45hex as 8Ahex. The read address would

be 8Bhex.

For more information on Phillips I

2

C please visit;

 ¢¡£¡¥¤§¦©¨£¨£§¤¢ !¢"¢¨¢#$¤¢£%£&£')(0¨12¢34¢5761¨12¢3¢$£8¢"79@A ¢¡B

2.3 General Purpose Outputs

The display has six general purpose outputs. These are provided to control relays or other electronic de-

vices. This allows external devices to be turned on or off using the PC or controller and software commands.

Each output is wired as shown in the Figure below. The + terminal is connected directly to the module

positive supply, the - terminal is connected through a 240 ohm current limiting resistor and the electronic

switch to ground.

Figure 10: General Purpose Outputs

Maximum allowable current is 20 mA, which is enforced by the current limiting resistor. If the device

being switched has a resistance of 240 ohms or more the corresponding resistor may be shorted. Solder a

small jumper wire (wirewrap wire is good) from the feedthrough hole to the corresponding negative pin for

the GPO in question.

Matrix Orbital

VK204-25

10