beautypg.com

8 general purpose output – Matrix Orbital GLK240128-25 User Manual

Page 42

background image

Command Summary

37

6.8 General Purpose Output

8.1 General Purpose
Output On

Dec
Hex
ASCII

254 87

FE 57

■ W

Number
Number
Number

v8.0

Turns the specified GPO on, sourcing current from an output of five volts.

Number

Byte

GPO to be turned on.


8.2 General Purpose
Output Off

Dec
Hex
ASCII

254 86

FE 56

■ V

Number
Number
Number

v8.0

Turns the specified GPO off, sinking current to an output of zero volts.

Number

Byte

GPO to be turned off.


8.3 Set Start Up
GPO State

Dec
Hex
ASCII

254 195

FE C3

■ ├

Number State
Number State
Number State

v8.0

Sets and saves the start up state of the specified GPO in non volatile memory. Changes will be seen on start up.

Number

Byte

GPO to be controlled.

State

Byte

1 for on or 0 for off.