Pinouts for connectors – Clary CMN2000IPA User Manual
Page 8
Page 8
PINOUTS FOR CONNECTORS
Load 1-4 37 Pin Connector
Load 5-8 37 Pin Connector
Pin 1 – Load 1 Line
Pin 1 – Load 5 Line
Pin 2 – Load 2 Line
Pin 2 – Load 6 Line
Pin 3 – Load 3 Line
Pin 3 – Load 7 Line
Pin 4 – Load 4 Line
Pin 4 – Load 8 Line
Pin 5 – Load 1 Neutral
Pin 5 – Load 5 Neutral
Pin 6 – Load 2 Neutral
Pin 6 – Load 6 Neutral
Pin 7 – Load 3 Neutral
Pin 7 – Load 7 Neutral
Pin 8 – Load 4 Neutral
Pin 8 – Load 8 Neutral
Pin 10 – Load 1 GND
Pin 10 – Load 5 GND
Pin 11 – Load 2 GND
Pin 11 – Load 6 GND
Pin 12 – Load 3 GND
Pin 12 – Load 7 GND
Pin 13 – Load 4 GND
Pin 13 – Load 8 GND
Pin 30 – Interlock 1-1
Pin 30 – Interlock 5-1
Pin 31 – Interlock 2-1
Pin 31 – Interlock 6-1
Pin 32 – Interlock 3-1
Pin 32 – Interlock 7-1
Pin 33 – Interlock 4-1
Pin 33 – Interlock 8-1
Pin 34 – Interlock 1-2
Pin 34 – Interlock 5-2
Pin 35 – Interlock 2-2
Pin 35 – Interlock 6-2
Pin 36 – Interlock 3-2
Pin 36 – Interlock 7-2
Pin 37 – Interlock 4-2
Pin 37 – Interlock 8-2
Ext. Fan 7 Pin Connector
Temp Sensor DB-9 Connector
Pin 1 – 115VAC Line
Pin 1 – Warm Sensor Return
Pin 2 – 115VAC Neutral
Pin 2 – Warm Sensor Input, Normal Open
Pin 4 – GND
Pin 4 – Hot Sensor Input, Normal Open
Pin 5 – +5VDC
Pin 5 – Hot Sensor Return
Pin 6 – FanFail/
Pin 6 - +5VDC
Pin 7 – +5VDC Return
Pin 7 - +5VDC Return
AC Input Connector
Pin 1 – 115VAC Line
Pin 2 – 115VAC Neutral
Pin 3 - GND