Cleanup, English, You will need – Wagner Power Painter User Manual
Page 10
English
10
© Wagner Spray Tech. - All Rights Reserved
Cleanup
You will need:
• Waste container
• Warm soapy water if you sprayed latex materials
• Mineral spirits if you sprayed oil-based materials
Make sure you clean the sprayer in a well-
ventilated area whenever cleaning with
flammable solvents.
The sprayer contains electrical parts.
DO nOT submerge the sprayer into any
liquids.
To Clean:
1. Unplug the sprayer. Pour the remaining material
back into the original container. Rinse the inside of
the cup with the appropriate cleaning solution.
2. Remove the suction tube.
3. Turn the spray tip counterclockwise until it is
removed. Pull the atomizer valve out, being careful
not to lose it.
4. Using the spray tip, turn the locking nut
counterclockwise until it is removed.
5. Slide the pump housing off the sprayer.
6. Remove all parts from the pump housing assembly.
Clean all parts thoroughly with the brush provided
using a solution appropriate to the type of material
you sprayed.
7. IMPORTanT: Make sure to completely remove
all material from the inside of the piston
chamber by scrubbing with the brush. Even a
small amount of material can dry like glue and
keep the piston from moving, causing damage
to the sprayer.
8. IMPORTanT: Make sure to keep the vent hole
(a) on the pump housing clean and unblocked
or a vacuum can build up in the container and
cause damage to the sprayer. a toothpick or
straightened paper clip can be used to clean it.
(a)
1
2
3
4
5
8
7
6