beautypg.com

Timing, Data, Strobe – MagTek TTL User Manual

Page 14: Card present, Figure 2-3. timing

background image

I/O Interface for TTL Magnetic Stripe Readers


10

TIMING

The timing for Card Present, Strobe, and Data is as shown in Figure 2-3.

CARD PRESENT



DATA



STROBE




1 1 1

0 0 0 0 0

1

1 0

0 0

0

0

Bit
Time

STROBE WIDTH APPROXIMATELY
25-50% OF BIT TIME


Notes:
1. Time out of the CARD PRESENT signal occurs approximately 150 ms after the last strobe transition.

2. DATA is valid 1.0

μ sec before the negative edge of STROBE.

Figure 2-3. Timing

DATA


The Data signal is valid while the strobe is low. If the Data signal is high, the bit is a zero. If the
Data signal is low, the bit is a one.

STROBE


The Strobe signal indicates when Data is valid. It is recommended that Data be loaded by the
user with the leading edge (negative) of the Strobe.

CARD PRESENT


Card Present will go low after 14/15 flux reversals from the head. Card Present will return high
150 milliseconds after the last flux reversal.