01 check the power to the micr reader, 02 read a check, 03 did pc receive data – MagTek MINI MICR RS232 User Manual
Page 49: 04 analyze data, Check the power to the micr reader, Read a check, Did pc receive data, Analyze data

MINI MICR RS232 with 3-Track MSR
42
01
CHECK THE POWER TO THE MICR READER
Possible causes for this problem are:
• AC adapter connection to outlet - make sure the AC adapter is securely connected to outlet
on the wall or power strip.
• AC adapter connection to MICR Reader - make sure the AC adapter is securely connected to
the power jack on the MICR Reader.
• Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and
the switch on the strip is turned on.
• AC adapter is defective - replace the AC adapter.
Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 00.
◊ If no, continue to step 17.
02
READ A CHECK
Read a check through the MICR Reader:
◊ If the check is transported all the way around the check path, continue to step 03.
◊ If the check gets "stuck" in the check path, continue to step 10.
◊ If the motor does not turn on, continue to step 17.
03
DID PC RECEIVE DATA?
After the check is read, did the PC receive any data?
◊ If yes, continue to step 04.
◊ If no, continue to step 05
04
ANALYZE DATA
Analyze the data received by the PC:
◊ If the data is good, continue to step 15.
◊ If the data contains one or more '?', continue to step 06.
◊ If the data is missing characters, continue to step 07.
◊ If the data is garbled, continue to step 08.
◊ If the data is good but not what is expected, continue to step 09.