Track id enable property – MagTek USB HID SURESWIPE & USB HID SWIPE READER User Manual
Page 28

USB HID Swipe Reader
22
card data transfer rate decreases the USB bus bandwidth used by the device.
The value of this property will be sent to the host when the host requests the
device’s USB endpoint descriptor.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
Example Set MAX PACKET SIZE property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
02
03
08
Example Set MAX PACKET SIZE property Response (Hex):
Result Code Data Len
Data
00
00
Example Get MAX PACKET SIZE property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
03
Example Get MAX PACKET SIZE property Response (Hex):
Result Code Data Len
Prp Value
00
01
08
TRACK ID ENABLE PROPERTY
Property ID:
0x04
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
95 (hex)
Description:
This property is defined as follows:
id
0
T
3
T
3
T
2
T
2
T
1
T
1
Id
0 – Decodes standard ISO/ABA cards only
1 – Decodes AAMV and 7-bit cards also
T
#
00 – Track Disabled
01 – Track Enabled
10 – Track Enabled/Required (Error if blank)
This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.